Home / Blog

how-to

How to Prepare Solar Panels for Severe Weather

How to Prepare Solar Panels for Severe Weather

Last Updated: November 21, 2026

Quick Summary

To learn how to prepare solar panels for severe weather, start about a week before a forecast storm by checking the inverter and monitoring app for faults, confirming mounting hardware is tight, and clearing loose debris. Trim overhanging branches well before storm season, and photograph the system so you have a record of its condition.

  • Begin storm preparation about a week before a forecast storm.
  • Check the inverter and monitoring app for existing faults or alerts.
  • Confirm mounting hardware and roof attachments are tight before severe weather.
  • Clear loose items from the roof and yard that could become flying debris.
  • Never climb onto a wet or icy roof to inspect panels.
Is your solar system ready for the next storm?Go Solar DMV helps DMV homeowners check and protect their rooftop solar systems.
Get Your Storm Check

Table of Contents

How Severe Weather Affects Solar Panels

Severe weather can damage solar panels in ways that are easy to miss from the ground, so learning how to prepare solar panels for severe weather starts with knowing what to look for.

The National Renewable Energy Laboratory says its storm-hardening checklists for solar photovoltaic systems are meant to help systems stay available after severe weather.

Hail, high winds, lightning, and cyclone-force gusts each stress a system in a different way. Wind load is usually the biggest concern for roof-mounted arrays, while hail mainly threatens the glass.

Solar Panel Storm Preparation Checklist

Learning how to prepare solar panels for severe weather works best when you start about a week before a forecast storm.

Homeowner inspecting solar panel mounting rails with a flashlight to learn how to prepare solar panels for severe weather.
Homeowner inspecting solar panel mounting rails with a flashlight to learn how to prepare solar panels for severe weather.

Use this checklist before severe weather:

  • Check the inverter and monitoring app for existing faults or alerts
  • Confirm the mounting hardware and roof attachments are tight
  • Clear loose items from the roof and yard that could become flying debris

Keep the list somewhere easy to find. A printed copy on the fridge works well during a fast-moving storm.

Inspecting Panels, Mounting Hardware and Wiring

Look at the array from the ground with binoculars first. Check for cracked glass, bent frames, and rails that look loose or out of line.

Wiring is harder to judge from the ground. Pests and nesting birds can also damage this area, so you may want to read our steps to stop birds from nesting near panels and wiring.

Clearing Debris and Trimming Overhanging Trees

Loose patio furniture, trash cans, and garden tools can become dangerous in high winds. Store them indoors or tie them down before the storm.

Branches that touch or hang over the array can break off and strike panels. Trim them well before storm season.

The steps below summarise the pre-storm checklist and when to act on each item.

Step What to do Time or frequency
Start preparing Begin storm preparation About a week before a forecast storm
Check inverter Check the inverter and monitoring app for faults Before severe weather
Check mounting Confirm mounting hardware and roof attachments are tight Before severe weather
Clear debris Remove loose items from roof and yard Before severe weather
Trim trees Trim limbs that hang over the array Well before storm season
Photograph system Record the system's condition Before severe weather
Know shutdown Know how to shut the system down safely Before severe weather

Protecting Solar Panels From Hail

Hail is one of the most common causes of cracked solar glass. Large or dense hailstones can still cause damage, so checking the glass for chips or cracks after a hailstorm is a sensible habit.

Panels that are cracked or chipped may lose output and can create safety risks. Cracked glass also lets moisture reach the internal components. Document any damage with photos and contact your installer and insurance company.

Securing Solar Panels Against High Winds and Hurricanes

Wind is the main threat to a roof-mounted system. Ask your installer whether your system was rated for the wind speeds common in your area.

Before a hurricane or strong wind event, check every clamp and bolt you can safely reach. Loose hardware is one of the first things to fail. For arrays on ground mounts, make sure the foundation and frame are stable.

Shutting Down Your System and Planning for Battery Backup

Shutdown is the step homeowners most often get wrong, because there is no single universal procedure. A string inverter, a microinverter system, and a hybrid inverter with battery backup each have different disconnects, and the order in which you open them matters. Once the system is set up, you can check battery charge and system status from your phone during and after a storm.

Why shutdown procedures vary by system

Most residential systems have two or three isolation points: a DC disconnect between the array and the inverter, an AC disconnect between the inverter and the main service panel, and the main breaker itself. Microinverter systems often have no central DC disconnect because each panel has its own inverter. Hybrid systems add a backup load panel and a battery disconnect. Because the sequence and location differ, a generic online checklist can be wrong for your equipment.

Watch out: never open a DC disconnect under load unless your instructions specifically say to, and never touch a disconnect, junction box, or wiring that is wet, scorched, or visibly damaged. DC arcs do not self-extinguish the way AC arcs do.

What happens to grid-tied solar during an outage

A common misconception is that a grid-tied system keeps producing power when the utility goes down. It does not. Under UL 1741, grid-tied inverters are required to include anti-islanding protection that shuts the inverter off within a couple of seconds of losing grid voltage, so the array cannot backfeed lines that utility crews are working on. That means your panels can be undamaged and still produce nothing during an outage.

Preparing a battery for a storm

If you have storage, treat the battery like a generator you have to fuel in advance:

  • Charge the battery to full before the storm arrives, and confirm the charge level in your monitoring app.
  • Decide which circuits are on the backup panel and test them once, well before storm season, so you know what the battery will actually carry.
  • Prioritize essential loads, refrigeration, medical equipment, communications, and a few lights, and plan to shed large loads like HVAC, electric ranges, and EV charging.

A shutdown timeline you can actually follow

  • A week out: locate your shutdown instructions, confirm the battery is charging, and test the backup circuits.
  • 24-48 hours out: charge the battery to full, clear debris, and photograph the system.
  • As the storm arrives: if your installer's instructions call for shutdown, perform the sequence in the written order and leave the system off until the storm passes.
  • After the storm: do not re-energize until you have visually inspected the array and confirmed there is no damage (see the inspection section below).

If you are a renter or your system is part of a shared or community array, you likely cannot access the disconnects. In that case, contact the system owner or property manager for the shutdown procedure and report any visible damage to them rather than attempting anything yourself.

Solar Panel Inspection After a Storm

Post-storm inspection is where most homeowners either skip steps or take unnecessary risks. The goal is not to repair anything yourself, it is to decide, safely and with a record, whether the system can be restarted or needs a professional. Work in this order.

1. Confirm it is safe to go outside

Wait until the storm has fully passed and local officials have lifted any warnings. Look up before you look at the array: downed power lines, leaning trees, and loose roof material are more dangerous than the panels themselves. Stay well away from any downed line and assume it is energized. If you see a line touching your array, racking, or conduit, do not approach the system, call the utility and your installer.

2. Do a ground-level visual check

From the ground, using binoculars if you have them, look for:

  • Cracked, chipped, or discolored glass on any panel
  • Panels that are displaced, tilted, or sitting out of line with their neighbors
  • Bent or separated rails, missing clamps, or lifted flashing at roof penetrations
  • Conduit that has pulled away from the wall or junction boxes that are open or full of water

Never climb onto a wet, icy, or damaged roof to get a closer look. A roof that held up to the wind may still have compromised decking or flashing.

3. Check the monitoring app before you touch anything

Compare current production against a clear day from the prior week. A sudden drop, a string that reads zero, or an inverter fault code is a signal to stop and call your installer. Record the readings, a screenshot with a timestamp is enough, because the pattern of what the system reported before and after the storm is often more useful to a technician than a single reading.

4. Document everything for insurance

Photograph the array from multiple angles, the inverter display, the monitoring app, and any debris or damage to the roof and yard. Note the date and time. Most homeowner policies cover wind and hail damage to rooftop solar, but claims go smoother when you can show the system's condition before the storm, which is why the pre-storm photo in the preparation checklist matters.

5. Decide whether to restart

Do not re-energize the system if you see any of the following:

  • Cracked glass or a panel that has shifted on its racking
  • Exposed or damaged wiring, or a junction box that took on water
  • A burning smell, scorch marks, or a tripped breaker that will not reset
  • An inverter fault that does not clear after a power cycle per the manufacturer's instructions

If none of those are present and the array looks intact, follow your installer's restart sequence, typically the reverse of the shutdown order. If you are unsure at any point, leave the system off. A day of lost production costs far less than a repair.

6. Know who to call

  • Your installer for any visible damage, inverter fault, or question about restarting.
  • Your utility if a power line is down or if you suspect damage to the service connection.
  • Your insurer once you have photos and a description of the damage, before authorizing repairs.
  • A licensed electrician or solar technician for anything involving wiring, disconnects, or the inverter.

For guidance on measuring whether your system is still performing as expected after a restart, see our article on solar panel system performance testing. If you find cracked glass, output drops, or inverter alerts, our guide on signs your solar panels need professional repair explains which checks to run first.

When to Call a Qualified Solar Technician

Call a qualified technician if you see cracked glass, loose or bent racking, exposed wiring, burning smells, or any inverter fault that does not clear. Never attempt electrical repairs yourself.

Homeowners in the DMV area can get a local solar quote from Go Solar DMV for a qualified installer to review their system.


Frequently Asked Questions

Can solar panels withstand high winds?

Most residential solar panels are engineered and tested to handle substantial wind loads, but the rating depends on the racking system, mounting hardware and how well the roof attachments were installed. Before a storm, check that clamps and bolts are tight and that no panels are loose or lifting. Loose components are the most common point of failure in high winds, so a professional inspection after installation or after a major wind event is a practical safeguard for your system.

Should I turn off my solar panels before a storm?

In most cases you do not need to shut down the whole system, but you should know how to do it safely. Many homeowners turn off the main inverter or the AC and DC disconnects only if they see visible damage, a burning smell or exposed wiring. Follow your installer's written shutdown instructions, and never climb onto the roof during or right after a storm. If you are unsure, contact a qualified technician before touching any electrical component.

Can hail damage solar panels?

Yes. Hail can crack tempered glass, damage cells and affect frames or junction boxes, especially with large stones. Most panels are tested against impact standards, but severe hail can still cause visible cracks or reduced output. After a hailstorm, look for cracked glass, chipped edges and any drop in production shown in your monitoring app, then document the damage with photos for your insurer.

Does homeowners insurance cover storm damage to solar panels?

Coverage depends on your policy and your state, so review your declarations page and ask your insurer whether solar equipment is included under dwelling coverage or needs a separate endorsement. Keep purchase records, installation documents and dated photos of the system before a storm. Documenting pre-storm condition and post-storm damage makes a claim much easier to support.

GoogleAdd gosolardmv.com as a preferred source on Google →